XSite 400

XSite

Download Recent Update

Latest Version: 4.00.19 (Description)
Released On: mercredi, mai 15, 2024

Supplemental Files

The following DLL library file must be installed before running XSite 4.0 for the first time.

msmpisetup.exe (5.9 MB, Stand-alone, redistributable and SDK installers for Microsoft MPI)

User Guide

Download the XSite 4.0 User's Guide (PDF, 6 MB).

Known Issues

  • The maximum proppant concentration is still hardwired to 0.7. It should probably increased to 1.0
  • Need to take a closer look at proppant stress when the new conductivity curves (indexed by proppant concentration and stress) are used.
  • Perforated tunnels:
    • Simplified logic cluster volume calculation needs to take in consideration that the part of the perf. tunnel cylinder is already taken into consideration by the borehole volume;
    • Generalize the logic for viscosity transition allowing switch from power-law fluid and include power-law fluid and fluid transition in the simplified logic; and
    • resetClusterOnNodes is called after a stage is inactivated; it probably should not to avoid premature connection of the active fractures with those connected with inactive clusters.
  • Export grid function is limited to infinite horizontal plane seams. Will added ability to specify export extent based on top and lower seam for minimum and maximum Z-coordinate and fractures location for X- and Y-coordinates.
XSite 4.00 64-bit Update

Software Update Revisions

Revision Date Description
19 mai 15, 2024
  • Updated user's guide
  • Fixed importing fracman
  • Added limit range to save/restore
  • Fixed history locations for fluidjoints
  • Fixed joints getting deleted if global coordinates were used with a rotation
18 avr. 24, 2024
  • Fixed reset temperature to properly use springs instead of nodes
  • Fixed display histories when no cluster exists
  • Added exact location of history tp the output of batch and console
  • Fixed pressure initialization of matrix pressure
  • Fixed limit range of of fracman dfn import, now limits springs on initialization rather than when importing
  • Added reset temperature to batch, save restore needs to be fixed
17 mars 22, 2024
  • Fixed crash when importing joints using dxf files
  • Removed broken example problems and fixed some
  • Fixed bug on sub-lattice zone initiation of joints
  • Added limit import range to import fracman DFN dialog
  • Fixed bug on sketch model when plotting boreholes with reference point and azimuth rotation
  • Added reset temperature to reset lattice, allowing temperature of segments to be set to fixed or to loose
16 mars 5, 2024
  • Added heal microcracks to batch
  • Updated Enable Multistep to Enable Multistepping During Advection Simulation
  • Fixed crash on running mechanical with fluid inactive
  • Fixed calibration mode not cracking properly
15 févr. 21, 2024
  • Fixed micro cracks counter when exporting micro cracks
  • Added check box to batch and reset lattice to import only connected micro cracks when importing initial state
  • Added heal microcracks to reset lattice for removing cracks that don't have pipes connected
14 févr. 15, 2024
  • Fixed initial state not importing proppant concentration
13 févr. 2, 2024
  • Fixed prevent micro cracking check box not being saved on restore
  • Added micro crack counter to micro crack export when using a grid
  • Fixed batch depletion workflow dialog box
12 janv. 19, 2024
  • Added fast pore pressure import method for rectangular and uniform grids
  • Fixed crash on proppant concentration plot item and importing from fluid nodes file
11 déc. 12, 2023
  • Fixed license dialog version
  • Updated thermal example in example files
  • When exporting microcracks with a grid, empty Joint List will show as N/A
  • Fixed bug when checking for joint intersection resulting in an undefined joint intersection angle
  • Fixed bug not allowing initial state to be loaded
  • Updated reset lattice dialog
  • Fixed import bug for MC files
  • Fixed permeability bug for importing multiple fracman dfns
10 nov. 28, 2023
  • Minor GUI changes
  • Excavate now deletes fluid nodes, pipes and fluid joint from liner
09 nov. 16, 2023
  • Added maximum number of mech interactions to reset lattice and batch dialog
  • Removed option to run 10000 mechanical steps if relative volume balance is greater than 10%
  • Fixed pump schedule import dialog
08 nov. 6, 2023
  • Fixed cluster fluid node activation
  • Update thermal options text on solutions tab
  • Fluid cycle during thermal equilibrium runs with allow aperture change only on first cycle
7 oct. 4, 2023
  • Pipes are impermeable if both fluid elements are impermeable. Pore pressure changes are calculated for impermeable fluid elements.
  • Fixed cluster issue not getting activated properly
  • Update for intel oneAPI 2023
  • Missing labels in hfconfig.xml
  • Removed libfabric from linuxdeploy.bat
6 sept. 12, 2023
  • Building w/ CMake
  • Using Github for subversion control
  • Fixed issue with wrong fluidnodes being calculated in implicit logic
  • Only fluid elements inside the perf tunnel or completion wil be skipped on the implicit calculations
  • Fixed bitmap exporter
  • Fixed dialogs for borehole import and wellgeometry import
5 juil. 31, 2023
  • Fixed display of demo mode watermark.
  • Enhanced console license security.
4 juil. 20, 2023
  • Fixed UI bugs causing crashing.
  • Added heat advection multistepping.
3 juil. 11, 2023
  • Added variable to store matrix pressure.
  • Added security to console version.
2 juin 13, 2023
  • Bug fix: Fixed Bitmap export crash.
1 juin 12, 2023
  • Updated from XSite 3.0.69.
  • Bug fix: the Matrix checkbox in the Features/Fluid tab will be unchecked after reloading a file following fluid injection.
  • Bug fixed: code was crashing during post-processing execution when exporting MC using grid file.
  • Bug fix: code was crashing when recreating fluid nodes when adaptive resolution was being applied to the model.
  • Bug fix: code was crashing stop simulation before it finishes and click on Reset Model. Reset the batch and when you execute it again.
  • Added checkbox on Features/Sink tab that will allow to activate the sink when the defined pressure is reached.
XSite Updates

Dernières Nouvelles
  • Itasca has announced the release of FLAC2D v9 Itasca has announced the release of FLAC2D v9, revolutionizing the way we analyze and predict...
    En savoir plus
  • 6th Itasca Symposium on Applied Numerical Modeling The next Itasca Symposium will take place June 3 - 6, 2024, in Toronto, Canada....
    En savoir plus
  • Itasca International Inc. announces the Selection of its New CEO Itasca International Inc. announces the nomination of its new CEO ...
    En savoir plus

Évènements à Venir
29 oct.
Getting Started with 3DEC
Objectives of the training: Understand the 3DEC numerical approach and the types of problems it can solveKnow how to manipulate the 3DE... En savoir plus
5 nov.
Python in Itasca Software
Cette formation vous donnera toutes les clés pour être capable d’utiliser Python afin d'étendre les capacités de simulation des logicie... En savoir plus
19 nov.
Getting Started with FLAC2D/FLAC3D
This training is an introduction to continuous modeling with FLAC2D and FLAC3D. At the end of the course, participants will master the ... En savoir plus